Transjugular intrahepatic portosystemic shunt (TIPS)

Definition

Transjugular intrahepatic portosystemic shunt (TIPS) is a procedure to create new connections between two blood vessels in your liver. You may need this procedure if you have severe liver problems.

Alternative Names

TIPS; Cirrhosis - TIPS; Liver failure - TIPS

Description

This is not a surgical procedure. It is done by an interventional radiologist using x-ray guidance. A radiologist is a doctor who uses imaging techniques to diagnose and treat diseases.

You will be asked to lie on your back. You will be connected to monitors that will check your heart rate and blood pressure.

You will probably receive local anesthesia and medicine to relax you. This will make you pain-free and sleepy. Or, you may have general anesthesia (asleep and pain-free).

During the procedure:

This new pathway will allow blood to flow better. It will ease pressure on the veins of your stomach, esophagus, intestines, and liver.

Why the Procedure Is Performed

Normally, blood coming from your esophagus, stomach, and intestines first flows through the liver. When your liver is very damaged and scar tissue blocks many of the small blood vessels in the liver, blood cannot flow through it very easily. This is called portal hypertension (increased pressure and backup of the portal vein). The veins can then break open (rupture), causing serious bleeding.

Common causes of portal hypertension are:

When portal hypertension occurs, you may have:

This procedure allows blood to flow better in your liver, stomach, esophagus, and intestines, and then back to your heart.

Risks

Possible risks with this procedure are:

Rare risks are:

Before the Procedure

Your health care provider may ask you to have these tests:

Tell your provider:

On the day of your procedure:

After the Procedure

After the procedure, you will recover in your hospital room. You will be monitored for bleeding. You will have to keep your head raised.

There is usually no pain after the procedure.

You will be able to go home when you feel better. This may be the day after the procedure.

Many people get back to their everyday activities in 7 to 10 days.

Your radiologist will probably recommend an ultrasound after the procedure to make sure the stent is working correctly.

You will be asked to have a repeat ultrasound in a few weeks to make sure that the TIPS procedure is working.

Outlook (Prognosis)

Your radiologist can tell you right away how well the procedure worked. Most people recover well.

TIPS works in about 80% to 90% of people with portal hypertension cases.

The procedure is much safer than surgery and does not involve any cutting or stitches.

References

Garcia-Tsao G. Cirrhosis and its sequelae. In: Goldman L, Cooney KA, eds. Goldman-Cecil Medicine. 27th ed. Philadelphia, PA: Elsevier; 2024:chap 139.

Kolarich AR, Tsitsiou Y, Georgiades C. Transjugular intrahepatic portosystemic shunt. In: Cameron JL, ed. Current Surgical Therapy. 14th ed. Philadelphia, PA: Elsevier; 2023:434-442.

Molano PB, Darcy M. Transjugular portosystemic shunting (TIPS): indications and technique. In: Jarnagin WR, Allen PJ, Chapman WC, et al, eds. Blumgart's Surgery of the Liver, Biliary Tract and Pancreas. 7th ed.  Philadelphia, PA: Elsevier; 2023:chap 85.


Review Date: 2/3/2025
Reviewed By: Jenifer K. Lehrer, MD, Gastroenterologist, Philadelphia, PA. Review provided by VeriMed Healthcare Network. Also reviewed by David C. Dugdale, MD, Medical Director, Brenda Conaway, Editorial Director, and the A.D.A.M. Editorial team.
The information provided herein should not be used during any medical emergency or for the diagnosis or treatment of any medical condition. A licensed medical professional should be consulted for diagnosis and treatment of any and all medical conditions. Links to other sites are provided for information only -- they do not constitute endorsements of those other sites. No warranty of any kind, either expressed or implied, is made as to the accuracy, reliability, timeliness, or correctness of any translations made by a third-party service of the information provided herein into any other language.

© 1997- A.D.A.M., a business unit of Ebix, Inc. Any duplication or distribution of the information contained herein is strictly prohibited.

All content on this site including text, images, graphics, audio, video, data, metadata, and compilations is protected by copyright and other intellectual property laws. You may view the content for personal, noncommercial use. Any other use requires prior written consent from Ebix. You may not copy, reproduce, distribute, transmit, display, publish, reverse-engineer, adapt, modify, store beyond ordinary browser caching, index, mine, scrape, or create derivative works from this content. You may not use automated tools to access or extract content, including to create embeddings, vectors, datasets, or indexes for retrieval systems. Use of any content for training, fine-tuning, calibrating, testing, evaluating, or improving AI systems of any kind is prohibited without express written consent. This includes large language models, machine learning models, neural networks, generative systems, retrieval-augmented systems, and any software that ingests content to produce outputs. Any unauthorized use of the content including AI-related use is a violation of our rights and may result in legal action, damages, and statutory penalties to the fullest extent permitted by law. Ebix reserves the right to enforce its rights through legal, technological, and contractual measures.
© 1997- adam.comAll rights reserved.